Vitaly:
That is exactly why people on shift need instructions and guidance about each sub-system from the expurts as what to look for constantly and regularly in their shifts. It is good that you guys found it only after few days instead of  weeks! 
---------- Original Message ----------------------------------
From: vitaliy ziskin <vziskin@mit.edu>
Date:  Fri, 27 Jun 2003 20:29:01 -0400
>Colleagues,
>I have a bad news.  Zhenya today found out that the rack with the 
>transition unit magnets' power supplies had tripped the circuit.  I'm 
>not sure exactly what happend, but it looks like the target magnets 
>which are in the same rack stayed on.  This makes sence since I think 
>those power supplies are on a different circuit breaker.  
>Anyway, I went back and checked at which point the magnets stopped 
>flipping.  It looks like it happened at 22:30 on the 25th of this month. 
> All data after that is as good a unpolarized.  Due to a low sensetivity 
>in the compression tube we probably could not tell if the transitions 
>were taking place.  I suggest the a shift takers check that the hall 
>probes in the transition units change thier value commensurate with the 
>compression tube and target bits.
>
>                                                    Best regards, 
>Vitaliy Ziskin
>
>