Hi, since the Apr 06 analysis meeting, I redid the unpol analysis. A new version
of show_buff_flow.C by Aki is used which I believe incoorperates more accurate
cell conductance calculations. the unpol runs are lrn-recrunched with the new
DCCT calibration. the results look much better this time. the recrunch also
brought back some missing cell temp epics info.
date         density        ed-rate      density      recovery-rate
         from buffer flow             from ed rate
            D/cm^2           /C            D/cm^2    
2004
May 11:     6.14e13         0.62         3.70e13      60%
May 11:     5.77e13         0.61         3.61e13      63%
Jun 03:     4.92e13         0.51         3.09e13      63%
Jun 07:     7.89e13         0.85         5.08e13      64%
Jun 26:     8.05e13         0.78         4.71e14      59%
Jul 14:     4.88e13         0.63         3.79e13      78%
Aug 08:     7.66e13         0.96         5.78e13      75%
Sep 07:     4.89e13         0.63         3.79e13      77%
Oct 05:     4.35e13         0.58         3.47e13      80%
2005
Apr 15:     5.21e13         0.51         3.07e13      59%
If you compare this to what I showed  on Apr-06, the major difference is in fact
in the target density computed from the buffer flow. So seems that our
efficiency was actually in 70-80% ballpark. Note that this is after trigger, WC,
tracking and a complete set of ed-elastic event selection rules.
The unpol took on Apr 15th, apart from the spin bits problem, Cell Temperature
Epics channel "ABS:TC2:QSAMP2.VAL" was invalidated. lrn has been using this
channel for cell temp. The result is that CellT in DST and ntuples are -1 all
the time.
Chi