Re: [BLAST_SHIFTS] Shift summary 10/24/2004 A (1-9)

From: Aaron Joseph Maschinot (ajmasch@MIT.EDU)
Date: Sun Oct 24 2004 - 09:17:37 EDT


my beautiful table got destroyed by the elog's haphazard use of tab's.
here it is again, hopefully more pretty this time...

date/time observation attempted fix result
--------------- ------------------ ------------------ ------------------
10/20/04 "bad" wc tdc turned wc gas left wc spectra
                spectra in right flow rate from 4 still fine; no
                sector to 5 liters/min change in "bad"
                                                      right wc spectra

10/21/04 still "bad" wc shut off gas flow right sector
                tdc spectra in entirely to left problem goes
                right sector sector; all gas away, but can't
                                   then flows into take two-sector
                                   right sector data like this

10/22/04 still "bad" wc install movable right sector
                tdc spectra in valve to allow problem not
                right sector us to choose fixed
                                   the fraction of
                                   gas going to
                                   each sector;
                                   valve initially
                                   set so as to
                                   form a 70 deg
                                   angle with
                                   mezzanine

10/23/04 still "bad" wc move valve so right sector
09:00 tdc spectra in as to form a 90 problem goes
                right sector deg angle with away, but can't
                                   mezzanine; gas take two-sector
                                   thus only goes data like this
                                   to right sector

10/23/04 still "bad" wc move valve so right sector
17:00 tdc spectra in as to form about problem nearly
                right sector a 85 deg angle all gone, but
                                   or so with left sector now
                                   mezzanine starts to look
                                                      bad

10/23/04 "bad" wc tdc move valve so right sector still
22:00 spectra in left as to form a 80 looks pretty
                sector deg angle or so good, but left
                                   with mezzanine sector shows
                                                      no change

10/24/04 "bad" wc tdc move valve so right sector still
02:30 spectra in left as to form a 75 looks pretty
                sector deg angle or so good, but left
                                   with mezzanine sector shows
                                                      no change

10/24/04 "bad" wc tdc move valve so ???
07:00 spectra in left as to form a 70
                sector deg angle or so
                                   with mezzanine