my beautiful table got destroyed by the elog's haphazard use of tab's.
here it is again, hopefully more pretty this time...
date/time observation attempted fix result
--------------- ------------------ ------------------ ------------------
10/20/04 "bad" wc tdc turned wc gas left wc spectra
spectra in right flow rate from 4 still fine; no
sector to 5 liters/min change in "bad"
right wc spectra
10/21/04 still "bad" wc shut off gas flow right sector
tdc spectra in entirely to left problem goes
right sector sector; all gas away, but can't
then flows into take two-sector
right sector data like this
10/22/04 still "bad" wc install movable right sector
tdc spectra in valve to allow problem not
right sector us to choose fixed
the fraction of
gas going to
each sector;
valve initially
set so as to
form a 70 deg
angle with
mezzanine
10/23/04 still "bad" wc move valve so right sector
09:00 tdc spectra in as to form a 90 problem goes
right sector deg angle with away, but can't
mezzanine; gas take two-sector
thus only goes data like this
to right sector
10/23/04 still "bad" wc move valve so right sector
17:00 tdc spectra in as to form about problem nearly
right sector a 85 deg angle all gone, but
or so with left sector now
mezzanine starts to look
bad
10/23/04 "bad" wc tdc move valve so right sector still
22:00 spectra in left as to form a 80 looks pretty
sector deg angle or so good, but left
with mezzanine sector shows
no change
10/24/04 "bad" wc tdc move valve so right sector still
02:30 spectra in left as to form a 75 looks pretty
sector deg angle or so good, but left
with mezzanine sector shows
no change
10/24/04 "bad" wc tdc move valve so ???
07:00 spectra in left as to form a 70
sector deg angle or so
with mezzanine