Hi Genya,
I analyzed the recent unpol runs and I see you point. I do find
1.5e16 molecule/second flow out of the buffer system, I do confirm that
3e16 atom/sec makes a 8e13 density in central 40cm of the cell. I do
confirm with this density, luminosity is 5e31 as you quoted.
I even confirm that I get 0.56 events/C with those series of unpol runs
which is comparable to the 0.53 /C I see from ABS runs.
leave alone the sqrt(2) factor in the Mass, I agree things match fairly
well. except that event rate does not seem to reflect the gas flow. Maybe
a leaking gas feed on unpol system?
However, please do note that the rate I finally get from both are both
bloody half event a coulumb. This by my computation implies 1.3e31
luminosity as oppose 5e31. But I quote a luminosity just to ease the
comparison to proposal and others. IMHO, it is the count rate that
matters. We see 0.53/C we should base our projection on that number.
Please let me know if you do see a lot more ed events than I do.
Chi
> Calibrated by data from unpol runs, the target flux F=3*10**16
> at/sec, total thickness in the
> area +- 2 cm from the center is about t=8*10**13 at/cm**2, and the
> luminosity at 100 mA is
> about 5*10**31. We expect to collect 300kC of data.