[BLAST_SHIFTS] Shift summary 05/08/2004 D (12-16)

From: Electronic Log Book (elog@blast05.lns.mit.edu)
Date: Sat May 08 2004 - 16:39:23 EDT


Operators: tavi chris2 ----

Took runs: 7276 7277 7279-7281 7283-7285
The low polarization might be due to the fact that scalers had the wrong scan value for abs variables. hauke fixed it (see his message). restarted run with fixed values. (chris2 elog#23766).
So, a good run to look at the polarization is 7285.
Since run#7280 the injected beam is 90mA (Vitali wants this), but since Hauke fixed that problem, we might want to go back to 110mA!!!



This archive was generated by hypermail 2.1.2 : Mon Feb 24 2014 - 14:07:31 EST