Hi,
I think something has happened to the electronics.map or the way
TBLRaw decodes it.
I have tried redirecting to the specific map in the elog/archive but
that doesn't help.
Anyway, it appears that raw.GetWCchamber(i) returns a value in the
range 0-2 rather than 0-5.
The effect is that the superlayer information is lost. This will make
reconstruction difficult.
I have only done this on runs 4226-4237 but I expect it is general.
If you run WC_quick.C you should see TDC and wire hits in all chambers,
all superlayers, all sectors.
Cheers,
Douglas
26-415 M.I.T.
Tel: +1 (617) 258-7199
77 Massachusetts Avenue Fax: +1 (617)
258-5440
Cambridge, MA 02139, USA E-mail:
hasell@mit.edu