Operators: degrush degrush ----
Continued taking ABS H2 data to measure ep asym:
RUNS:3516,3517 3519-3522 3524-3526 3528 3531-3530
Need to generate more statistics (see results sent by PK)
WC: Still have good S/B and has been relatively free from tripping.
LADS L15_R1 Down 's voltage was set to -1680 and written to the database using the hv gui.
NOTE: Although not normally advised, you can changes made to the hv save sets by :
1.) Set the state you wish to make changed to (OPER or STANDBY)
2.) Change the values you want in the set window (DV,TC, Rup, Rdn,). NOTE: CE is not part of the save sets. To "disable" a channel set the voltage to zero.
3.) Click the grey save button to make it part of the current save set.
4.) Click the General Control Window in the upper-right hand corner of the main control screen.
5.)Press either the "STORE STBY" or "STORE OPER" depending on what change you just made.