Re: [BLAST_SHIFTS] WC tripping

From: Adrian T Sindile (asindile@cisunix.unh.edu)
Date: Sun Jun 22 2003 - 14:02:23 EDT


> I checked the settings and the problem is most likely due to the run voltage
> in the new database being set to 3900 V. I changed it to 3800 V so a reboot
> should fix it.

Well, nobody told me it should be 3800 V (not 3900 V)... This "new"
database has been sitting there for a month, so except for the changes
Adam asked for two days ago, that's what we have (I hope other people have
been updating voltages for their systems too, if they needed tweaking -
I am thinking mostly of Cerenkovs).
It's great Adam tracked this down.

Adrian

>
> Cheers,
> Adam
>
>
>
>
> Douglas Hasell wrote:
>
> > Why are the WC's tripping? Are the BQM rates normal? The correct
> > operating mode is that the WC's are ramped down to 2000 V during injection
> > and then normal operating voltages for running. If a box trips during
> > running try lowering the operating voltage 100 V for a few fills and then
> > gradually (25 V steps) raise it again so long as it holds. All last week
> > this worked and most of the time all boxes worked and trips were very
> > infrequent.
> >
> > Are the WC STBY settings 2000 V ?
> >
> > Since we have changed the HV GUI to use the physics database this may not
> > have been updated. Adrian ?
> >
> > To check the WC STBY voltages when not taking data:
> > 1 - click STBY on the main HV GUI window
> > 2 - wait for the restore in progress to finish
> > 3 - click on the WC L button
> > 4 - you should get a new window with MV DV and CE for each WC box
> > 5 - click on DISPLAY button to request current reading
> > 6 - MV and DV should be 2000 V
> > 7 - if it is not click on SET
> > 8 - new window should appear allowing you to set DV, TC, RUP, etc.
> > 9 - click on DV to allow demand voltages to be set
> > 10 - change all values to 2000 V (NOTE the cursor has to stay in
> > the little box as you change the value and you have to hit return each time
> > for the change to take affect - sorry it is EPICS)
> > 11 - after changing all the values click SET
> > 12 - close the setting window
> > 13 - in the read value window clicking on DISPLAY should show the
> > new DV values as 2000 V if it doesn't go back to point 7 and try again
> > 14 - once all values are set properly return to the main window and
> > click on the set beside the WC L button
> > 15 - in the top left corner of the main HV window there is a button
> > for saving settings, click this
> > 16 - click SAVE STBY settings (I don't think saving to database
> > works - Adam?) and the close window
> > 15 - go back to point 3 and repeat for WC R
> >
> > If you reboot the HV IOC or reinitialize from the database you
> > loose these settings and it has to be done again.
> >
> > If you try to do this during auto-fill running you will run out of
> > time when it is in STBY and the automatic program will restore OPER values
> > and ruin everything.
> >
> > Cheers,
> > Douglas
> >