[BLAST_SHIFTS] HITs vs TOF online

From: Peter Karpius (karpiusp@einstein.unh.edu)
Date: Wed May 07 2003 - 20:24:46 EDT


Hi all-

        After VZ got TS's etSPy sample code test.C working I grabbed the
important parts and now have a rudimentary macro for TOF data quality.
(This is the macro I showed in the morning meeting a few weeks ago except
now it is online). With regards to the macro:

1) it plots hits vs. TOF requiring TDC (100-4095) and ADC (1000-8190)
   I chose these values as the macro is not yet set up to read in the
   thresholds / offsets.

2) The code is called hits_vs_TOF_ONLINE.C and is in /pro2003/etSpy/

3) usage(with a run going): root hits_vs_TOF_ONLINE.C (on dblast07)

4) This can easily include other detectors as well - I will work in that.

                                        Try it out when on shift!
        
                                        Pete

                
                
                                        
                
          
----------------------------------------------
Pete Karpius
Graduate Research Assistant
Nuclear Physics Group
University of New Hampshire
phone: (603)862-1220
FAX: (603)862-2998
email: karpiusp@einstein.unh.edu
http://pubpages.unh.edu/~pkarpius/homepage.htm
----------------------------------------------