I added adc sum<5000 to LC0 too, there is a slight improvement but not
very mush. I figured 60%, 65%, what s the difference given a lot
uncertainties elsewhere.
But it does change results for LC1 significantly, from ~50% to ~70%.
On Sun, 27 Oct 2002, Tancredi Botto wrote:
>
> well, I meant no elastic protons. But I stand corrected: you can get
> n-delta and wall protons of course. So an ADC cut could be useful for LC1
> and RC1, not needed for LC0 and RC0 ? That is actually something I
> neglected in my on-shift analysis, where I was more focussed on background
> and timing,
>
> any takers ?
>
>
This archive was generated by hypermail 2.1.2 : Mon Feb 24 2014 - 14:07:28 EST