Chris D'Andrea, Nikolas meiTanis
Gain matched both right and left side TOFS to pedestal+1300.
Only Left TOP seems to be rather erratic (see logbook) and may need
further investigation. Goal was to get to 1300 within 50 channels.
Considering the RMS of some of these values this seems to be slightly
ambitious.
These values still need to be recorded in an sql file. They are recorded
in the logbook.
Raised the cerenkov voltage by 5% and 10% in seperate runs, TOF at +1300..
Noticed that
at these voltages LC1 TOP was fluctuating 2 orders of magnitude (~3*10^6)
higher than the rest of the boxes. Reduced the voltage to manufacturers
recommended voltages and while the LC1TOP box was lowered to the level the
other boxes held previously, the other boxes seemed to low.
Took a long cosmics run with manufacturers recommended voltages and TOF at
+1300.
The CCr is searching the hall at 7:20am.
Note that all runs done with cosmics.
Also, changed the plot_adc_ntp.C to calculate the MPV of the Landau for
the adc and the mean of the gaussian for the pedestal.See file.