[BLAST_CODA] another tpye of coda hang (?)

From: Tancredi Botto (tancredi@mitlns.mit.edu)
Date: Wed Aug 07 2002 - 20:30:41 EDT


I've apparently experienced another type of "hang". After
so many evts (30K) Coda differential rate went to zero and
the screen stop updating (that I believe I've not seen before)

Waited a copuple of minutes but coda would not kick back in
as it did earlier in the run during a "sleep". Rate was
100 Hz/25 and Kbytes/s

Tried to pause, failed, end of run was not possible anymore (reset
and re-started running). So I believe now that coda could really hang
in the middle of a run (not just at the beginning)

-tancredi

WARN : blastROCr has not reported status for 337 seconds
ERROR : blastROCr is in state disconnected should be active
WARN : blastROC has not reported status for 1413 seconds
ERROR : blastROC is in state disconnected should be active
ERROR : Pause : TS subsystem(s) timeout !!!(45 45 1000)
ERROR : TS : subsystem failed in activating state
WARN : blastROC has not reported status for 1416 seconds
WARN : blastROCr has not reported status for 340 seconds
ERROR : ROC : subsystem failed in dormant state
ERROR : EB : subsystem failed in active state
ERROR : ER : subsystem failed in active state
ERROR : Pause failed !!!
INFO : blastER reset ......
INFO : blastER reset ok
INFO : blastEB reset ......

-- 
________________________________________________________________________________
Tancredi Botto,  		phone: +1-617-253-9204    fax: +1-617-253-9599
research scientist		MIT/Bates, 21 Manning Av   Middleton MA, 01949
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^